Interscanner variation in brain MRI lesion load measurements in MS: Implications for clinical trials
Citation Manager Formats
Make Comment
See Comments
This article requires a subscription to view the full text. If you have a subscription you may use the login form below to view the article. Access to this article can also be purchased.
Abstract
We evaluated the effect of interscanner variation on brain MRI-measured lesion volumes and measurement reproducibility in MS. Twenty clinically definite MS patients were each scanned on two or three scanners (a total of 14 scanners were used). In addition, a formalin-fixed MS brain was studied on eight scanners from different manufacturers and with different field strengths. For the formalin-fixed MS brain, on each machine we obtained two scans with slice thicknesses of 5 and 3 mm. Only 5-mm-thick slices were obtained from patients. The lesion volume present on each scan was evaluated three times by a single observer in random order, using a local thresholding technique. In two groups of eight patients scanned on machines with different field strengths, the mean lesion volumes present on scans obtained at 1.5 T were significantly higher than those measured on scans obtained with machines operating at 0.5 and 1.0 T (p < 0.01). When a single observer repeatedly evaluated the same scan, a median intraobserver agreement of 98.7%(95% CI, 97.9 to 99.1) was achieved. However, when the observer evaluated the scans from different MRI scanners, the agreement (an interscanner agreement) fell to 91.1% (CI, 90.2 to 94.1). When only scanners operating at 1.5 T were considered, the median interscanner agreement was 96.7% (CI, 95 to 97.5). Also, for the formalin-fixed MS brain, the intraobserver agreements obtained with both slice thicknesses were significantly higher than the corresponding interscanner agreements. The interscanner agreement, but not the intraobserver agreement, obtained with a slice thickness of 3 mm was higher than that obtained with a slice thickness of 5 mm. Our results indicate that lesion volume measurements in MS are influenced significantly by the use of different MR scanners and that a patient included in a serial study should be always scanned with the same MR machine using 3-mm thick slices.
AAN Members
We have changed the login procedure to improve access between AAN.com and the Neurology journals. If you are experiencing issues, please log out of AAN.com and clear history and cookies. (For instructions by browser, please click the instruction pages below). After clearing, choose preferred Journal and select login for AAN Members. You will be redirected to a login page where you can log in with your AAN ID number and password. When you are returned to the Journal, your name should appear at the top right of the page.
AAN Non-Member Subscribers
Purchase access
For assistance, please contact:
AAN Members (800) 879-1960 or (612) 928-6000 (International)
Non-AAN Member subscribers (800) 638-3030 or (301) 223-2300 option 3, select 1 (international)
Sign Up
Information on how to subscribe to Neurology and Neurology: Clinical Practice can be found here
Purchase
Individual access to articles is available through the Add to Cart option on the article page. Access for 1 day (from the computer you are currently using) is US$ 39.00. Pay-per-view content is for the use of the payee only, and content may not be further distributed by print or electronic means. The payee may view, download, and/or print the article for his/her personal, scholarly, research, and educational use. Distributing copies (electronic or otherwise) of the article is not allowed.
Letters: Rapid online correspondence
REQUIREMENTS
You must ensure that your Disclosures have been updated within the previous six months. Please go to our Submission Site to add or update your Disclosure information.
Your co-authors must send a completed Publishing Agreement Form to Neurology Staff (not necessary for the lead/corresponding author as the form below will suffice) before you upload your comment.
If you are responding to a comment that was written about an article you originally authored:
You (and co-authors) do not need to fill out forms or check disclosures as author forms are still valid
and apply to letter.
Submission specifications:
- Submissions must be < 200 words with < 5 references. Reference 1 must be the article on which you are commenting.
- Submissions should not have more than 5 authors. (Exception: original author replies can include all original authors of the article)
- Submit only on articles published within 6 months of issue date.
- Do not be redundant. Read any comments already posted on the article prior to submission.
- Submitted comments are subject to editing and editor review prior to posting.
You May Also be Interested in
Dr. Dennis Bourdette and Dr. Lindsey Wooliscroft
► Watch
Related Articles
- No related articles found.
Alert Me
Recommended articles
-
Article
Accumulation of hypointense lesions ("black holes") on T1 spin-echo MRI correlates with disease progression in multiple sclerosisL. Truyen, J. H.T.M. van Waesberghe, M.A.A. van Walderveen et al.Neurology, December 01, 1996 -
Articles
Primary and transitional progressive MSA clinical and MRI cross-sectional studyV.L. Stevenson, D.H. Miller, M. Rovaris et al.Neurology, March 01, 1999 -
Articles
Effect of training and different measurement strategies on the reproducibility of brain MRI lesion load measurements in multiple sclerosisM. Filippi, M. L. Gawne-Cain, C. Gasperini et al.Neurology, January 01, 1998 -
Brief Communications
The effect of imprecise repositioning on lesion volume measurements in patients with multiple sclerosisM. Filippi, N. Marcianò, R. Capra et al.Neurology, July 01, 1997