11C-flumazenil PET in patients with refractory temporal lobe epilepsy and normal MRI
Citation Manager Formats
Make Comment
See Comments
This article requires a subscription to view the full text. If you have a subscription you may use the login form below to view the article. Access to this article can also be purchased.
Abstract
Background: Using 11C-flumazenil (FMZ) PET with correction for partial-volume effect, reductions of central benzodiazepine receptor (cBZR) binding can be detected reliably in vivo on remaining neurons in sclerotic hippocampi of patients with mesial temporal lobe epilepsy (TLE).
Objective: To delineate abnormalities of 11C-FMZ binding in patients with medically refractory TLE and normal quantitative MRI.
Methods: Analysis of parametric images of FMZ volume of distribution (Vd) using two complementary approaches: 1) MRI-based volume of interest (VOI) approach with partial volume effect correction for multiple hippocampal and extrahippocampal VOIs; and 2) statistical parametric mapping (SPM) to localize significant 11C-FMZ binding changes objectively on a voxel-by-voxel basis.
Results: Significant abnormalities of absolute FMZ-Vd were found after partial volume effect correction in 5 of 10 patients: unilateral decrease in the amygdala ipsilateral to the EEG focus (1), unilateral hippocampal decreases and bilateral temporal and extratemporal neocortical decreases (2), unilateral increase in the temporal neocortex together with extratemporal neocortical increases (1), and bilateral posterior hippocampal increases together with temporal neocortical increases (1). In the three patients with extratemporal neocortical changes, the concomitant unilateral hippocampal or temporal neocortical changes were contralateral to the presumed epileptic focus. Significant asymmetries of FMZ-Vd between homologous regions were found in six patients. In four of those patients, absolute FMZ-Vd for the homologous regions were within normal limits, with two of the four patients showing relatively higher hippocampal values ipsilateral to the presumed epileptic focus. SPM analysis localized significant abnormalities of FMZ-Vd in similar locations in three of the seven patients in whom VOI analysis detected significant changes. In addition, SPM indicated significant unilateral contralateral hippocampal decreases in an eighth patient. However, both methods failed to localize epileptic foci in two patients identified by depth-EEG recordings.
Conclusions: 11C-FMZ PET showed focal increases as well as decreases of FMZ binding in 80% of patients with refractory TLE and normal high-quality MRI but was not consistently helpful in localizing the epileptic foci.
- Received February 18, 1999.
- Accepted August 27, 1999.
AAN Members
We have changed the login procedure to improve access between AAN.com and the Neurology journals. If you are experiencing issues, please log out of AAN.com and clear history and cookies. (For instructions by browser, please click the instruction pages below). After clearing, choose preferred Journal and select login for AAN Members. You will be redirected to a login page where you can log in with your AAN ID number and password. When you are returned to the Journal, your name should appear at the top right of the page.
AAN Non-Member Subscribers
Purchase access
For assistance, please contact:
AAN Members (800) 879-1960 or (612) 928-6000 (International)
Non-AAN Member subscribers (800) 638-3030 or (301) 223-2300 option 3, select 1 (international)
Sign Up
Information on how to subscribe to Neurology and Neurology: Clinical Practice can be found here
Purchase
Individual access to articles is available through the Add to Cart option on the article page. Access for 1 day (from the computer you are currently using) is US$ 39.00. Pay-per-view content is for the use of the payee only, and content may not be further distributed by print or electronic means. The payee may view, download, and/or print the article for his/her personal, scholarly, research, and educational use. Distributing copies (electronic or otherwise) of the article is not allowed.
Letters: Rapid online correspondence
REQUIREMENTS
You must ensure that your Disclosures have been updated within the previous six months. Please go to our Submission Site to add or update your Disclosure information.
Your co-authors must send a completed Publishing Agreement Form to Neurology Staff (not necessary for the lead/corresponding author as the form below will suffice) before you upload your comment.
If you are responding to a comment that was written about an article you originally authored:
You (and co-authors) do not need to fill out forms or check disclosures as author forms are still valid
and apply to letter.
Submission specifications:
- Submissions must be < 200 words with < 5 references. Reference 1 must be the article on which you are commenting.
- Submissions should not have more than 5 authors. (Exception: original author replies can include all original authors of the article)
- Submit only on articles published within 6 months of issue date.
- Do not be redundant. Read any comments already posted on the article prior to submission.
- Submitted comments are subject to editing and editor review prior to posting.
You May Also be Interested in
Dr. Sevil Yaşar and Dr. Behnam Sabayan
► Watch
Related Articles
- No related articles found.
Alert Me
Recommended articles
-
Articles
Neocortical abnormalities of [11C]-flumazenil PET in mesial temporal lobe epilepsyA. Hammers, M.J. Koepp, C. Labbé et al.Neurology, April 10, 2001 -
Articles
11C-flumazenil PET, volumetric MRI, and quantitative pathology in mesial temporal lobe epilepsyM. J. Koepp, M. P. Richardson, C. Labbé et al.Neurology, September 01, 1997 -
Articles
Glucose and [11C]flumazenil positron emission tomography abnormalities of thalamic nuclei in temporal lobe epilepsyC. Juhász, F. Nagy, C. Watson et al.Neurology, December 01, 1999 -
Articles
Electroclinical correlates of flumazenil and fluorodeoxyglucose PET abnormalities in lesional epilepsyC. Juhász, D.C. Chugani, O. Muzik et al.Neurology, September 26, 2000